At Align Technology, we listen and value your feedback. We are
committed to continuously
improving Invisalign experience. We are pleased to introduce the
new features available in
Invisalign Doctor Site (IDS) and ClinCheck software.
Update on Clinical Preference
In Invisalign Doctor Site (IDS) under Clinical Preferences page, we have
added two new
questions on optimised attachment sizes and distorted molar handling.
In clinical preference
you can choose regular or larger sized optimised
attachment.*
* Single mesio-distal root control optimized attachments for upper and lower
laterals, canines and premolars. And multiplane and retention attachments
for laterals.
You can also advise our
technicians on how to handle distorted molar records.
Improved Attachment Visualization
In an effort to ensure you have a better visualization on the attachments ,
we have made improvements on ClinCheck and Tooth Chart .
You will be able to see
the attachments that need to be removed in translucent
colour on stage 0 on the
3D model in the Additional Aligner order. If there are new
attachments being placed, they will show on top of the
attachments
that need to be removed.
Newly added lingual
tooth chart on the Invisalign treatment overview. You
will be able to see the attachments you request to be placed
on the lingual side on the tooth chart under the treatment
requirement.
Overject and Overbite Clinical Parameters Indication
Now you will be able to see the value of clinical parameters for
Overjet and Overbite in ClinCheck.
* The single values in the table are the average of both upper central incisors.